• DocumentCode
    3570440
  • Title

    Fermilab collider Run 1b statistics

  • Author

    Bharadwaj, V. ; Crawford, J. ; Mau, R.

  • Author_Institution
    Fermi Nat. Accel. Lab., Batavia, IL, USA
  • Volume
    1
  • fYear
    1995
  • Firstpage
    443
  • Abstract
    The present Fermilab Tevatron Collider run, designated as Run 1b, started in October 1993 and will conclude in July 1995. This paper summarizes the parameters and performance of the Fermilab accelerator complex to date. Operational problems encountered during the run are described as well as the factors that limit peak and delivered luminosities
  • Keywords
    colliding beam accelerators; proton accelerators; storage rings; synchrotrons; Fermilab accelerator complex; Fermilab collider Run 1b statistics; Tevatron; integrated luminosities; peak luminosity; performance numbers; Colliding beam accelerators; Laboratories; Lightning; Particle beams; Power supplies; Proton accelerators; Stacking; Statistics; Storage rings; Synchrotrons;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1995., Proceedings of the 1995
  • Print_ISBN
    0-7803-2934-1
  • Type

    conf

  • DOI
    10.1109/PAC.1995.504685
  • Filename
    504685