DocumentCode :
3570720
Title :
Impact of Generator Distance Phase Backup Protection on Generator Overexcitation Thermal Capability during System Disturbances
Author :
Elsamahy, Mohamed
Author_Institution :
Dept. of Electr. Power & Machines, Higher Inst. of Eng., Al Shorouk, Egypt
fYear :
2014
Firstpage :
30
Lastpage :
34
Abstract :
In this paper investigations are carried out to explore the generalization of the adverse impact of the existing setting of the generator distance phase backup protection (Relay (21)) according to the existing standards on generator over excitation thermal capability during system disturbances. These investigations are conducted in two stages, the first includes a SMIB system incorporating a midpoint STATCOM in order to increasing its power transfer capability. The second includes a multi-generator power plant configuration. Both stages have included the performance of Relay (21), during two common system disturbances, namely a system fault and a sudden application of a large system load while the generator over excitation limiter (OEL) is in service. The results of this paper have generalized the restricting impact of the current setting of Relay (21) on the over excitation thermal capability of the generator during system disturbances. Moreover, results also have proven that in-depth stability studies are of high paramount for selecting Relay (21) setting which will allow the generator to ful fill adequate level of voltage stability during system disturbances.
Keywords :
hydroelectric generators; power generation faults; power generation reliability; power system stability; relay protection; static VAr compensators; OEL; SMIB system disturbance; STATCOM; generator distance phase backup protection; generator overexcitation thermal capability; hydroelectric generator overexcitation limiter; in-depth stability; multigenerator power plant configuration; power system fault; power transfer capability; relay protection performance; static synchronous compensator; voltage stability; Automatic voltage control; Generators; Impedance; Loading; Power transmission lines; Relays; Trajectory; Generator distance phase backup protection; Generator overexcitation thermal capability; generator overexcitation limiters (OEL); generator steady-state capability limit; static synchronous compensator (STATCOM);
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Power and Energy Conference (EPEC), 2014 IEEE
Type :
conf
DOI :
10.1109/EPEC.2014.28