DocumentCode
357133
Title
Some aspects of bulk cable current injection (BCCI) test method at system level testing of an aircraft
Author
Pande, D.C. ; Aravind, M.K.
Author_Institution
Electron. & Radar Dev. Establ., Bangalore, India
fYear
1999
fDate
6-8 Dec. 1999
Firstpage
29
Lastpage
34
Abstract
The Bulk Cable Current Injection (BCCI) testing, at equipment/subsystems/system level has been recognised as a promising technique in lieu of radiated susceptibility testing upto few hundreds of MHz. Although it is an efficient technique for the evaluation of electromagnetic susceptibility (EMS) of the system, but at the same time due to its instrumentation particularly bulky and heavy current injection and monitoring probes, put a restriction to the use of BCCI, in the integrated system testing. In this paper, the use of BCCI test facility for integrated aircraft testing has been critically analysed and discussed. Problems which may arise due to the generation of strong harmonic products up to HF band in BCCI testing also have been discussed with their solutions.
Keywords
aircraft testing; BCCI testing; HF band; aircraft; bulk cable current injection test instrumentation; electromagnetic susceptibility; harmonic product; system-level testing; Aerospace electronics; Aircraft; Electromagnetic radiation; Hafnium; Instruments; Medical services; Monitoring; Probes; System testing; Test facilities;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Interference and Compatibility '99. Proceedings of the International Conference on
Print_ISBN
81-900652-0-3
Type
conf
DOI
10.1109/ICEMIC.1999.871591
Filename
871591
Link To Document