• DocumentCode
    357135
  • Title

    EMI problems and control methods in data acquisition systems

  • Author

    Mourougayane, K. ; Karunakaran, S.

  • Author_Institution
    Commun. Syst. & Projects Div., SAMEER, Chennai, India
  • fYear
    1999
  • fDate
    6-8 Dec. 1999
  • Firstpage
    39
  • Lastpage
    42
  • Abstract
    Data Acquisition System (DAS) involves measurement of different types of signals whose level will vary from sensitive low voltage to dangerous high voltage sharing common ground. Poor grounding and isolation between channels, between channel to earth results in false and inaccurate representation of acquired signals. Proper use and implementation of signal conditioning methods helped in eliminating problems related to ground loop and common mode voltages. The Electromagnetic interference (EMI) problems encountered in the development of Data acquisition systems and the techniques followed to control the noise will be discussed.
  • Keywords
    data acquisition; electromagnetic interference; interference suppression; data acquisition system; electromagnetic interference; noise control; signal conditioning; Control systems; Data acquisition; Electromagnetic interference; Electromagnetic measurements; Low voltage; Switches; Switching converters; Testing; Transducers; Uninterruptible power systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Interference and Compatibility '99. Proceedings of the International Conference on
  • Print_ISBN
    81-900652-0-3
  • Type

    conf

  • DOI
    10.1109/ICEMIC.1999.871593
  • Filename
    871593