Title :
Comparison of measured and calculated dynamic aperture
Author_Institution :
DESY, Hamburg, Germany
Abstract :
Dynamic aperture experiments at the Fermilab Main Ring, the Tevatron, the SPS and HERA are reviewed and compared with simulations. The agreement between experiments with additional strong nonlinearities and corresponding simulations is fairly good, if the relevant parameters are sufficiently well known and included in the model. Direct comparison is more problematic if machines under normal operating conditions with relatively weak non-linear fields are considered. Nevertheless, the agreement is reasonable and discrepancies can be accounted for by known imperfections of the model
Keywords :
electron accelerators; particle beam dynamics; proton accelerators; storage rings; synchrotrons; Fermilab Main Ring; HERA; SPS; Tevatron; dynamic aperture; simulations; strong nonlinearities; weak nonlinear fields; Apertures; Extraterrestrial measurements; Magnetic field measurement; Optical beams; Optical distortion; Optical scattering; Particle accelerators; Power system simulation; Stability; Superconducting magnets;
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Print_ISBN :
0-7803-2934-1
DOI :
10.1109/PAC.1995.505680