DocumentCode
3572359
Title
Study on Design the Stop Pipe Diameter of Packaging Viscous Fluid
Author
Fu-Xin, Yang ; Sheng-Ze, Wang
Author_Institution
Coll. of Mech. Eng., Donghua Univ., Shanghai, China
Volume
3
fYear
2009
Firstpage
353
Lastpage
355
Abstract
The distribution of the speed and shear stress in viscous fluid with the laminar flow in the pipe were analyzed in this paper, then, the flow rate was calculated. Moreover, the stop pipe diameter was designed by calculating the balance of shear stress of viscous fluid in the pipe and the gravity of filling fluid. Analysis have The conclusions : stop pipe diameter of viscous fluid is proportional to viscosity and the square root of pipe length, and is inversely proportional to the acceleration of gravity and the square root of the filling factor.
Keywords
design engineering; laminar flow; packaging; pipe flow; pipes; flow rate; laminar flow; mechanized packing operation; packaging machinery; packaging viscous fluid; pipe flow; shear stress; stop pipe diameter; Filling; Food technology; Gravity; Machinery; Marine technology; Packaging machines; Pollution measurement; Sea surface; Stress; Viscosity; diameter; flow rate; speed; stress; viscous fluid;