• DocumentCode
    3572359
  • Title

    Study on Design the Stop Pipe Diameter of Packaging Viscous Fluid

  • Author

    Fu-Xin, Yang ; Sheng-Ze, Wang

  • Author_Institution
    Coll. of Mech. Eng., Donghua Univ., Shanghai, China
  • Volume
    3
  • fYear
    2009
  • Firstpage
    353
  • Lastpage
    355
  • Abstract
    The distribution of the speed and shear stress in viscous fluid with the laminar flow in the pipe were analyzed in this paper, then, the flow rate was calculated. Moreover, the stop pipe diameter was designed by calculating the balance of shear stress of viscous fluid in the pipe and the gravity of filling fluid. Analysis have The conclusions : stop pipe diameter of viscous fluid is proportional to viscosity and the square root of pipe length, and is inversely proportional to the acceleration of gravity and the square root of the filling factor.
  • Keywords
    design engineering; laminar flow; packaging; pipe flow; pipes; flow rate; laminar flow; mechanized packing operation; packaging machinery; packaging viscous fluid; pipe flow; shear stress; stop pipe diameter; Filling; Food technology; Gravity; Machinery; Marine technology; Packaging machines; Pollution measurement; Sea surface; Stress; Viscosity; diameter; flow rate; speed; stress; viscous fluid;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Intelligent Computation Technology and Automation, 2009. ICICTA '09. Second International Conference on
  • Print_ISBN
    978-0-7695-3804-4
  • Type

    conf

  • DOI
    10.1109/ICICTA.2009.552
  • Filename
    5287979