• DocumentCode
    3573537
  • Title

    The model and optimization of Monel K500 alloy heat treatment

  • Author

    Hong-Ru Li ; Wei-Nan Bai

  • Author_Institution
    Sch. of Inf. Sci. & Eng., Northeastern Univ., Shenyang, China
  • fYear
    2014
  • Firstpage
    4915
  • Lastpage
    4920
  • Abstract
    This paper optimized the heat treatment process based on the existing equipment and strictly controlling the quality indicators. There are seven quality prediction models were established by selecting heating temperature, heating rate and the holding time as the optimization of the decision variables. The optimization objective function of the Monel K500 alloy which is the most economy was established by the lowest energy consumption. Finally we solved the minimum energy consumption operational parameters.
  • Keywords
    copper alloys; energy consumption; heat treatment; nickel alloys; quality control; Monel K500 alloy heat treatment; decision variable optimization; heating rate; heating temperature; holding time; minimum energy consumption operational parameters; optimization objective function; quality indicator control; quality prediction model; Educational institutions; Heat engines; Heat treatment; Information science; Metals; Optimization; Predictive models; Economic optimization; Heat treatment; Monel K500; Prediction model;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Intelligent Control and Automation (WCICA), 2014 11th World Congress on
  • Type

    conf

  • DOI
    10.1109/WCICA.2014.7053547
  • Filename