Title :
Initiation of discharge inside the switches at low pressure
Author :
Arefjev, A.S. ; Baranov, A.N. ; Vereschagin, N.M.
Author_Institution :
Radioeng. Acad., Ryazan, Russia
Abstract :
The most important parameter of such devices as the thyratron and pseudo-spark gap is the switching time. This parameter depends on a design of the device, pressure and type of filling gas. Its magnitude is defined by the plasma formation time and determines the magnitude of pulse forward front of a voltage on loading and the magnitude of starting losses of power. Carrying out optimization of the circuit of the pulse generator using the thyratrons it is possible to considerably reduce finishing (after impulse) losses of the power in it, however to reduce starting losses is possible only by reduction of switching time. In this paper the experimental study of the process of switching inside the thyratron is discussed
Keywords :
discharges (electric); losses; pulse generators; pulsed power supplies; pulsed power switches; thyratrons; discharge initiation; filling gas; low pressure; plasma formation time; pseudo-spark gap; pulse forward voltage front; pulse generator circuit optimization; starting losses; switches; switching time; thyratron; Anodes; Cathodes; Electrical resistance measurement; Pulse circuits; Pulse generation; Pulse measurements; Pulse modulation; Switches; Thyratrons; Voltage;
Conference_Titel :
Discharges and Electrical Insulation in Vacuum, 2000. Proceedings. ISDEIV. XIXth International Symposium on
Conference_Location :
Xi´an
Print_ISBN :
0-7803-5791-4
DOI :
10.1109/DEIV.2000.877320