DocumentCode
3583508
Title
Magnetic induction monitor measurements of beam spatial characteristics in technological electron linear accelerators
Author
Boriskin, V.N. ; Gurin, V.A. ; Dovbnya, A.N. ; Popenko, V.A. ; Reprintsev, L.V. ; Savchenko, A.N. ; Stepin, D.L. ; Tatanov, V.I. ; Shendrik, V.A.
Author_Institution
NSC Kharkov Inst. of Phys. & Technol., Ukraine
Volume
2
fYear
2001
fDate
6/23/1905 12:00:00 AM
Firstpage
1336
Abstract
A high-current two-section pulsed electron linear accelerator (ELA) "EPOS" has been in successful operation at "Accelerator" R&D Production Establishment, NSC KIPT, for a few years. Its main parameters are the current pulse length -4 μs, the pulse current 0.4 to 1 A, the pulse recurrence rate -150 Hz, the electron energy - up to 30 MeV. To provide a safe beam guiding, four-winding magnetic induction monitors were devised, making possible measurements of the position of the beam current center relative to the accelerator axis with an error of ±0.5 mm at the input and output of the second accelerating section. At present, the "Accelerator" specialists have developed a compact two-section ELA "KUT-20", at the output of which a similar magnetic induction monitor is installed. Below, we present the results of bench calibration of the monitor as well as the experimental results of measuring-channel operation at the "EPOS" accelerator. The possibility of determining the second moment, which characterizes the difference of the beam cross section from its axially symmetric section, is demonstrated
Keywords
accelerator control systems; calibration; electron accelerators; electron beams; linear accelerators; particle beam diagnostics; particle beam dynamics; particle beam stability; 0 to 30 MeV; 0.4 to 1 A; 150 Hz; 4 mus; ELA; EPOS; accelerator axis; beam spatial characteristics; bench calibration; current pulse length; electron energy; high-current two-section pulsed electron linear accelerator; magnetic induction monitor measurements; measuring-channel operation; pulse current; pulse recurrence rate; safe beam guide; technological electron linear accelerators; winding magnetic induction monitors; Acceleration; Accelerator magnets; Calibration; Current measurement; Electron accelerators; Linear accelerators; Monitoring; Particle beams; Position measurement; Production;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001
Print_ISBN
0-7803-7191-7
Type
conf
DOI
10.1109/PAC.2001.986672
Filename
986672
Link To Document