  • Title

    Effects of transverse beam size in beam position monitors

  • Author

    Kurennoy, Sergey S.

  • Author_Institution
    Los Alamos Nat. Lab., NM, USA
  • Volume
    2
  • fYear
    2001
  • fDate
    6/23/1905 12:00:00 AM
  • Firstpage
    1372
  • Abstract
    The fields produced by a long beam,with a given transverse charge distribution in a homogeneous vacuum chamber are studied. Signals induced by the displaced finite-size beam on electrodes of a beam position monitor (BPM) are calculated and compared to those from a pencil beam. The non-linearities and corrections to BPM signals due to a finite transverse beam size are calculated for an arbitrary chamber cross section. Simple analytical expressions are given for a few particular transverse distributions of the beam current in a circular or rectangular chamber. Of particular interest is a general proof that in an arbitrary homogeneous chamber the beam-size corrections vanish for any axisymmetric beam current distribution
  • Keywords
    ion accelerators; particle beam diagnostics; storage rings; analytical expressions; arbitrary chamber cross section; axisymmetric beam current distribution; beam position monitor; beam-size corrections; circular chamber; displaced finite-size beam; finite transverse beam size; homogeneous chamber; homogeneous vacuum chamber; pencil beam; rectangular chamber; transverse charge distribution; transverse distributions; Current distribution; Electrodes; Electrostatics; Frequency; Linear accelerators; Linear particle accelerator; Particle beam measurements; Signal analysis; Storage rings; US Department of Energy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001
  • Print_ISBN
    0-7803-7191-7
  • Type

    conf

  • DOI
    10.1109/PAC.2001.986684
  • Filename
    986684