DocumentCode
3584105
Title
Consolidation project of the electrostatic septa in the CERN PS ring
Author
Borburgh, J. ; Hourican, M. ; Thivent, M.
Author_Institution
CERN, Geneva, Switzerland
Volume
2
fYear
2001
fDate
6/23/1905 12:00:00 AM
Firstpage
1541
Abstract
After almost two decades of reliable service, the electrostatic septa of the CERN PS complex need to be upgraded. This is to fulfil the increased requirements on vacuum performance and the need to reduce the time spent on maintenance interventions. Two electrostatic septa are used in the PS ring: septum 23 is used for a resonant slow extraction, while septum 31 is used for the so-called ´continuous transfer´ (CT) 5-turn extraction. This paper describes the experience gained with these septa over the years. We report the main characteristics and technological advantages of the new septum 23, together with its present performance
Keywords
electrostatic lenses; particle beam extraction; proton accelerators; synchrotrons; 5-turn extraction; CERN PS ring; consolidation project; continuous transfer; electrostatic septa; maintenance interventions; proton synchrotron; resonant slow extraction; vacuum performance; Assembly; Cables; Cathodes; Electrostatics; Maintenance; Petroleum; Resonance; Sparks; Vacuum systems; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001
Print_ISBN
0-7803-7191-7
Type
conf
DOI
10.1109/PAC.2001.986741
Filename
986741
Link To Document