• DocumentCode
    3584540
  • Title

    The operation of plastic MSGCs at high rates

  • Author

    Taylor, S.C. ; Armitage, J.C. ; Batchelar, D. ; Dixit, M.S. ; Dubeau, J. ; Estabrook, P.G. ; Henderson, C. ; Karlen, D. ; Muench, J.L. ; Oakham, F.G. ; Salomon, M. ; Stuart, G.C.

  • Author_Institution
    Dept. of Phys., Carleton Univ., Ottawa, Ont., Canada
  • Volume
    1
  • fYear
    1994
  • Firstpage
    443
  • Abstract
    The operation of MicroStrip Gas Counters (MSGCs) on a Upilex (polyimide) substrate is described. The surface resistivity of the substrate was reduced by ion implantation or by coating with a thin film of nickel oxide. Results are presented concerning the surface resistivity and its stability. The lowering of the substrate resistivity allows MSGCs to operate at very high rates and several devices were tested in a high flux X-ray beam. Substrates with optimum resistivity showed no gain changes whereas gain changes were seen on those with higher resistivity
  • Keywords
    X-ray detection; position sensitive particle detectors; proportional counters; Upilex; high flux X-ray beam; ion implantation; plastic microstrip gas counters; polyimide; substrate resistivity; surface resistivity; Coatings; Conductivity; Counting circuits; Ion implantation; Microstrip; Nickel; Plastic films; Polyimides; Stability; Substrates;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1994., 1994 IEEE Conference Record
  • Print_ISBN
    0-7803-2544-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1994.474343
  • Filename
    474343