DocumentCode
3584772
Title
Influence of load impedances on the quality of Power Line Communication
Author
Bouassam, Hamid ; Rifi, Mounir ; Degardin, Virginie
Author_Institution
Lab. RITM, Hassan II Univ., Casablanca, Morocco
fYear
2014
Firstpage
1
Lastpage
4
Abstract
Advanced communication technologies have allowed power-line-communication (PLC) channel to be a transmission medium that enables the transfer of high-speed digital data over the classical indoor electrical wires. The development of PLC systems for Internet, voice, and data services requires measurement-based models of the transfer characteristics of the mains network suitable for performance analysis by simulation. This paper presents the impact of load impedances connected on the electrical network on insertion gain and capacity of the PLC link.
Keywords
Internet telephony; carrier transmission on power lines; power supply quality; Internet; PLC link capacity; PLC systems; data services; electrical network; high-speed digital data transfer; indoor electrical wires; insertion gain; load impedances; measurement-based models; performance analysis; power line communication quality; power-line-communication channel; transmission medium; voice services; Current measurement; Gain; Laboratories; Load modeling; Noise; Plugs; Power line communications; Power Line Communication (PLC); channel capacity; channel characteristics; channel measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Sciences and Technologies in Maghreb (CISTEM), 2014 International Conference on
Type
conf
DOI
10.1109/CISTEM.2014.7076988
Filename
7076988
Link To Document