DocumentCode
3586128
Title
Direct torque control of three-phase PMSM with one switch of inverter open fault
Author
Moujahed, Mongi ; Ben Azza, Hechmi ; Jemli, Mohamed ; Boussak, Mohamed
Author_Institution
Unite de Rech. en Commande, Ecole Nat. Super. des Ing. de Tunis (ENSIT), Tunis, Tunisia
fYear
2014
Firstpage
400
Lastpage
404
Abstract
In this paper, direct torque control (DTC) of a three phase permanent magnet synchronous motor (PMSM) one switch open-circuit fault is described. An extra inverter leg is employed to provide the current path during the fault operation.
Keywords
invertors; machine control; permanent magnet motors; synchronous motors; torque control; direct torque control; inverter leg; inverter open fault; one switch open-circuit fault; permanent magnet synchronous motor; three-phase PMSM; Indexes; Inverters; Robustness; Switches; Synchronous motors; Thyristors; Torque; Direct Torque Control (DTC); FTC; Permanent Magnets Synchronous Machine (PMSM);
fLanguage
English
Publisher
ieee
Conference_Titel
Sciences and Techniques of Automatic Control and Computer Engineering (STA), 2014 15th International Conference on
Type
conf
DOI
10.1109/STA.2014.7086736
Filename
7086736
Link To Document