Abstract :
There are two approaches to the mitigation of power quality problems. The first approach is called load conditioning, which ensures that the equipment is less sensitive to power disturbances, allowing the operation even under significant voltage distortion. The other solution is to install line conditioning systems that suppress or counteracts the power system disturbances. A flexible and versatile solution to voltage quality problems is offered by active power filters AF. Currently they are based on PWM converters and connect to low and medium voltage distribution system in shunt or in series. Shunt Active Power Filters (SAPF) operate as a controllable current source. The Shunt AF filters can be used in multilevel mode to enhance the power quality. Cascaded multilevel Inverter is used as Shunt Active Power Filter to compensate the voltage sag during the presence of non-linear loads with reduced harmonics. Five level and seven level cascaded H-bridge multilevel inverter are used as SAPF. The number of levels in cascaded multilevel inverter is increased to reduce THD. The simulation is carried out in MATLAB/Simulink platform and the simulation results are presented in this paper.
Keywords :
PWM invertors; PWM power convertors; constant current sources; harmonic distortion; power harmonic filters; power supply quality; power system faults; MATLAB-Simulink platform; PWM converters; SAPF; cascaded H-bridge multilevel inverter; cascaded multilevel inverter; controllable current source; frequency 50 Hz; hybrid shunt active filter; line conditioning systems; load conditioning; low voltage distribution system; medium voltage distribution system; nonlinear loads; power disturbances; power quality problems; power system disturbance; shunt active power filters; voltage 415 V; voltage distortion; voltage quality problems; voltage sag; wire distribution systems; Active filters; Harmonic analysis; Inverters; Power harmonic filters; Reactive power; Voltage fluctuations; Active Power Filter (APF); Distributed Generators (DG); Hysteresis Current Control (HCC); Voltage Regulation (VR) and Total Harmonic Distortion (THD);
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Emerging Trends In New & Renewable Energy Sources And Energy Management (NCET NRES EM), 2014 IEEE National Conference On
Print_ISBN :
978-1-4799-8193-9
Type :
conf
DOI :
10.1109/NCETNRESEM.2014.7088767
Filename :
7088767
Link To Document :
بازگشت