DocumentCode :
3588582
Title :
A new front-end high-resolution sampling board for the new-generation electronics of EXOGAM2 and NEDA detectors
Author :
Egea, F.J. ; Gonzalez, V. ; Tripon, M. ; Jastrzab, M. ; Triossi, A. ; Gadea, A. ; de France, G. ; Valiente-Dobon, J.J. ; Blasco, J.M. ; Barrientos, D. ; Sanchis, E. ; Boujrad, A. ; Houarner, C. ; Blaizot, M. ; Bourgault, P. ; de Angelis, G. ; Erduran, M.N
Author_Institution :
Dept. d´Eng. Electron., Univ. de Valencia, Burjassot, Spain
fYear :
2014
Firstpage :
1
Lastpage :
3
Abstract :
The present paper aims to present the final design and results of the FADC Mezzanine for EXOGAM and NEDA detectors, focusing on the resolution performance. Finally, the conclusion shows how a common digitizing device has been integrated in an experimental environment involving low-noise and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but also, it shows how a study of synergy between detectors has led to a reduction of resources and time by applying a common strategy.
Keywords :
integration; nuclear electronics; particle detectors; EXOGAM2 detector; FADC Mezzanine; NEDA detector; digitizing device; front-end high-resolution sampling; integration; new-generation electronics; Detectors; Neutrons; Noise; Performance evaluation; Physics; Standards; Timing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Real Time Conference (RT), 2014 19th IEEE-NPSS
Print_ISBN :
978-1-4799-3658-8
Type :
conf
DOI :
10.1109/RTC.2014.7097539
Filename :
7097539
Link To Document :
بازگشت