DocumentCode
3590130
Title
Improving the protective performance of the Gas turbine and HRSG trip from hydraulic damper closing in power plant
Author
Phoosomma, Prasit ; Leeragreephol, Surachart
Author_Institution
Dept. of Ind. Technol., Dhonburi Rajaphat Univ., Bangkok, Thailand
fYear
2012
Firstpage
1503
Lastpage
1505
Abstract
After using low frequency switching circuit technique [2] to solved the problem of accumulated heat transfer in solenoid coil of the solenoid valve controlling hydraulic damper. This paper presents an improvement of switching circuit performance by adding the voltage supply comparator for more reliable of power supply to the solenoid coil and still save the energy loss in solenoid coil of the solenoid valve and completely protect the gas turbine trip from hydraulic damper closing failure and heat recovery steam generator (HRSG) trip.
Keywords
gas turbines; heat recovery; power generation protection; power supplies to apparatus; solenoids; valves; HRSG trip; accumulated heat transfer; energy loss; gas turbine trip; heat recovery steam generator trip; hydraulic damper closing failure; low frequency switching circuit technique; power plant; power supply; protective performance; solenoid coil; solenoid valve; voltage supply comparator; Coils; Control systems; Power generation; Shock absorbers; Solenoids; Switching circuits; Valves; Combine Cycle Power Plant; Gas turbine; Heat Recovery Steam Generator (HRSG); Solenoid Valve;
fLanguage
English
Publisher
ieee
Conference_Titel
Control, Automation and Systems (ICCAS), 2012 12th International Conference on
Print_ISBN
978-1-4673-2247-8
Type
conf
Filename
6393075