DocumentCode :
35903
Title :
Shielding effect of power transformers tanks in the ultra-high-frequency detection of partial discharges
Author :
Robles, G. ; Albarracin, R. ; Martinez-Tarifa, J.M.
Author_Institution :
Electr. Eng. Dept., Univ. Carlos III de Madrid, Leganés, Spain
Volume :
20
Issue :
2
fYear :
2013
fDate :
Apr-13
Firstpage :
678
Lastpage :
684
Abstract :
Partial discharges (PD) measurement is a well-known technique for judgment of the condition of power transformer offline. Phase-resolved PD measurement is a normalized technique for PD tests, but noise, especially by PD-measurements onsite is sometimes difficult to reject, and a post-processing of a pattern is necessary to separate different sources. Higher-frequency-detection devices and processing strategies are useful for PD classification and identification. Recently, ultra-high-frequency (UHF) detection by means of antennas has been shown to be a promising detection system for both offline and online PD-measurements. However, it is necessary to assess whether PD source separation and classification is possible by means of pulse analysis because some additional UHF noise sources are coupled to the detected signals, and it is not clear whether different sources produce different pulses. In this study, the attenuation effect of the metallic tank of a power transformer on the inner PD activity when measured outside the tank was studied. Additionally, experiments were conducted to detect and characterize two different PD sources (internal and external discharges) using two antennas measuring the same phenomenon inside and outside of a transformer. It will also be shown that broadband UHF signals are useful for PD recognition and that a deep study of frequencies below 500 MHz can separate PD occurring inside from those occurring outside when measured with an antenna outside the tank.
Keywords :
UHF antennas; UHF measurement; partial discharge measurement; power transformers; shielding; signal detection; source separation; PD recognition; PD source separation; PD test; UHF detection; UHF noise sources; antennas; attenuation effect; broadband UHF signals; metallic tank; offline PD-measurements; online PD-measurements; partial discharge measurement; phase-resolved PD measurement; power transformer tanks; shielding effect; signal detection; ultrahigh-frequency-detection devices; Antenna measurements; Antennas; Oil insulation; Partial discharges; Power transformer insulation; UHF measurements; UHF measurements; antennas; partial discharges; shielding;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/TDEI.2013.6508772
Filename :
6508772