    Operating temperature of PV module modified with surface cooling unit in real time condition

  • Author

    Sharma, Madhu ; Bansal, Kamal ; Buddhi, Dharam

  • Author_Institution
    Electr., Power &Energy, Univ. of Pet. & Energy Studies, Dehradun, India
  • fYear
    2014
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    High operating temperature decreases photo voltaic module efficiency. Normal Operating Cell Temperature, NOCT of silicon crystalline is about 49°C as reported. A cooling unit with reverse flow water circulation is designed, fabricated and applied on PV back surface to partially avoid undesirable effect of its temperature increase. This modified module with cooling unit and similar non-cooled modules are installed outdoor identically at University of Petroleum and Energy Studies campus, Dehradun. Installed Normal Operating Cell Temperature, INOCT of both the modules are determined and compared by varying water flow rate from cooling unit. And also water flow rate is optimized to maintain minimum possible operating temperature.
  • Keywords
    cooling; elemental semiconductors; silicon; solar cells; Dehradun; INOCT; PV module operating temperature; Si; installed normal operating cell temperature; normal operating cell temperature; photovoltaic module efficiency backsurface; reverse flow water circulation; silicon crystalline NOCT; surface cooling unit; water flow rate; Cooling; Photovoltaic systems; Temperature distribution; Temperature measurement; Wind speed; INOCT; PV module; optimum mass flow rate; passive surface cooling unit;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics (IICPE), 2014 IEEE 6th India International Conference on
  • Print_ISBN
    978-1-4799-6045-3
  • Type

    conf

  • DOI
    10.1109/IICPE.2014.7115790
  • Filename
    7115790