• DocumentCode
    3591403
  • Title

    Thermodynamic study of compound Mica — Epoxy Resin based on dissipation factor tests — Internal energy

  • Author

    Reyno, H.J. ; Amortegui, F.J.

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Nat. Univ. of Colombia, Santafé d Bogota, Colombia
  • fYear
    2014
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    In this paper an electrical equivalent of the internal energy based on dissipation factor tests of compound Mica - Epoxy Resin used as insulating material in the stator bars of electrical machines is shown. To this, 15 samples were designed and subjected to Step Voltage Endurance Test (SVET) at a constant temperature of 90°C. Before and during each period of aging, the dielectric losses by means of dissipation factor test of each sample were measured at a voltage of 2 kV, where it assumes the non-presence of partial discharges within the material, and within a temperature range. The results of the dielectric losses were used to determine the caloric coefficients and glass transition temperature of the material for the different stages of aging of the insulation.
  • Keywords
    dielectric losses; epoxy insulation; epoxy insulators; insulating materials; stators; thermodynamics; caloric coefficients; compound mica-epoxy resin; dielectric losses; dissipation factor tests; glass transition temperature; insulating material; step voltage endurance test; temperature 90 degC; thermodynamic study; voltage 2 kV; Aging; Dielectric losses; Glass; Insulation; Temperature; Temperature measurement; Internal energy; Step voltage endurance test; caloric coefficients; dielectric losses; glass transition temperature; insulation aging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power India International Conference (PIICON), 2014 6th IEEE
  • Print_ISBN
    978-1-4799-6041-5
  • Type

    conf

  • DOI
    10.1109/34084POWERI.2014.7117628
  • Filename
    7117628