• DocumentCode
    3591404
  • Title

    Thermodynamic study of compound Mica — Epoxy Resin based on dissipation factor tests — Enthalpy

  • Author

    Reyno, H.J. ; Amortegui, F.J.

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Nat. Univ. of Colombia, Santafé d Bogota, Colombia
  • fYear
    2014
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    In this paper an electrical equivalent of the enthalpy based on dissipation factor tests of compound Mica-Epoxy Resin used as insulating material in the stator bars of electrical machines is shown. To this, 15 samples were designed and subjected to Step Voltage Endurance Test (SVET) at a constant temperature of 90°C. Before and during each period of aging, the dielectric losses of each of the sample were measured at different voltages from 2 to 10 kV in a temperature range. The results of the dielectric loss were used to determine the caloric coefficients Kv and the glass transition temperature Tg of the material. The incidence of partial discharge based on the Tip-Up on these parameters in the various stages of aging of the insulation is analysed as well.
  • Keywords
    cooling; dielectric losses; enthalpy; mica; partial discharges; resins; SVET; compound mica-epoxy resin; dielectric losses; dissipation factor tests; electrical machines; enthalpy; insulating material; partial discharge; stator bars; step voltage endurance test; Aging; Dielectric losses; Insulation; Partial discharges; Temperature; Temperature measurement; Enthalpy; Step voltage endurance test; caloric coefficient; dielectric losses; glass transition temperature; insulation aging; partial discharge;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power India International Conference (PIICON), 2014 6th IEEE
  • Print_ISBN
    978-1-4799-6041-5
  • Type

    conf

  • DOI
    10.1109/34084POWERI.2014.7117629
  • Filename
    7117629