DocumentCode
3592324
Title
Full-scale test and research on transmission tower for UHV AC test and pilot Project
Author
Jingdu, Geng ; Qinghua, Li ; Zhenfu, Li
Author_Institution
China Electr. Power Res. Inst., Beijing, China
fYear
2010
Firstpage
1
Lastpage
7
Abstract
It´s the first used in 1000kV Transmission Line in China. To verify the validity of optimize, calculate and select material in UHV AC test and pilot project tower, choose several typical towers to conduct test and research. This article Through analyze the test data, it provides optimize proposal, reference for UHV tower design.
Keywords
optimisation; poles and towers; power cable testing; power transmission lines; UHV AC test; full scale test; optimization; pilot project; transmission line; transmission tower; voltage 1000 kV; Load modeling; Poles and towers; Reliability engineering; Optimization of Structure Design; Transmission Tower Full-scale Test; UHV AC Test and pilot Project; joint Construction;
fLanguage
English
Publisher
ieee
Conference_Titel
Electricity Distribution (CICED), 2010 China International Conference on
Print_ISBN
978-1-4577-0066-8
Type
conf
Filename
5735913
Link To Document