DocumentCode :
3592915
Title :
Impact of high frequency transducer on capillary design
Author :
Guan, Tan Kim
Author_Institution :
Logic Segment Dept., Infineon Technol. (Adv. Logic) Sdn Bhd, Melaka, Malaysia
fYear :
2014
Firstpage :
1
Lastpage :
4
Abstract :
Higher transducer frequency on the wire bonder is developed and introduced into the market. One of the key driving forces is to reduce the bonding time for higher uph especially for Cu wire bonding. On the other hand, there are few capillary outline designs are deployed newly to reduce displacement in order to achieve efficient energy transmission. The special capillary outline design is necessary to minimize any pre-damage on the active metal line structure underneath of the bond pad. The selection of capillary outline design becomes more crucial and cautious when wire bonder with high transducer frequency is being deployed. This paper will study the interaction of two transducer frequencies (>130KHz and <;130kHz) and two different capillary outline designs bonding on sensitive bond pad metal structure design. The sensitive bond pad metal structure design required some capillary outline design changes as compared to the traditional standard capillary outline design. Initial study compares the process window range during the initial process optimization cycle with different capillary outline design with high frequency transducer of >130Khz. The results shown there is significant difference of parameter window range between different capillary outline design. Capillary vibration check also carried out by using laser vibrometer. The vibration amplitude is being measured on the capillary tip as well as on the transducer with US fix setting. This paper also studies and compares the amplication ratio.
Keywords :
lead bonding; transducers; vibration measurement; vibrations; US fix setting; active metal line structure; amplication ratio; bond pad; bond pad metal structure design; bonding time reduction; capillary outline design selection; capillary tip; capillary vibration check; copper wire bonding; displacement reduction; energy transmission; high-frequency transducer; initial process optimization cycle; laser vibrometer; parameter window range; pre-damage minimization; process window range; vibration amplitude; wire bonder; Bonding; Copper; Frequency measurement; Transducers; Vibration measurement; Vibrations; Wires;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronics Manufacturing Technology Conference (IEMT), 2014 IEEE 36th International
Type :
conf
DOI :
10.1109/IEMT.2014.7123123
Filename :
7123123
Link To Document :
بازگشت