Title :
Combined methods for recovery of gastric slow waves from multichannel electrogastrograms
Author :
Lin, Zhiyue ; Liang, Hualou ; McCallum, Richard W
Author_Institution :
Det. of Med., Kansas Univ. Med. Center, Kansas City, KS, USA
fDate :
6/22/1905 12:00:00 AM
Abstract :
The electrogastrogram (EGG), a cutaneous measurement of gastric electrical activity, is a mixture of gastric slow waves and noise. To detect the propagation of gastric slow waves, it is necessary to obtain multichannel gastric slow waves from multichannel EGGs. In this paper, a combined method for recovery of multichannel gastric signals is presented. This method consists of a novel blind source separation method and an adaptive noise canceller. The main advantage of the proposed method is that no prior knowledge on the structure of sources is needed. The results from both computer simulations and real EGG data demonstrate the combined method is able to recover gastric slow waves from each of multichannel EGGs. Therefore, the proposed method can be used to detect propagation of gastric slow waves from multichannel EGGs
Keywords :
adaptive signal processing; bioelectric potentials; medical signal detection; medical signal processing; skin; EGG; adaptive noise canceller; blind source separation method; combined methods; computer simulations; cutaneous measurement; gastric electrical activity; gastric slow waves; multichannel electrogastrograms; noise; real EGG data; recovery; Blind source separation; Computer simulation; Electric variables measurement; Electrocardiography; Frequency; Humans; Independent component analysis; Noise cancellation; Source separation; Stomach;
Conference_Titel :
Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
Print_ISBN :
0-7803-6465-1
DOI :
10.1109/IEMBS.2000.897987