DocumentCode
3594129
Title
Experimental measurements of the ORION photoinjector drive laser oscillator subsystem
Author
Palmer, Dennis T. ; Akre, Ron
Author_Institution
Stanford Linear Accelerator Center, CA, USA
Volume
3
fYear
2003
Firstpage
2107
Abstract
Timing jitter measurements have been conducted on the ORION photoinjector laser oscillator pulse train output with respect to a ultra low noise crystal rf oscillator running at 79 1/3 MHz, the 36th harmonic of S-Band. The ORION laser oscillator subsystem consists of a Spectra-Physics Tsunami ultra-fast tunable (750 - 850 nm) laser pumped by a diode pumped Spectra-Physics Millennia VsP 5 W. Overall laser oscillator subsystem performance will be presented. These measurements consist of the laser oscillator generated noise and transfer function from the RF reference input of the laser to an external photodiode RF output. Timing jitter measurements of less than 500 fsec have been attained with the laser oscillator tuned to 800 nm.
Keywords
accelerator RF systems; optical pulse generation; optical pumping; optical transfer function; particle beam diagnostics; particle beam injection; phase noise; photodiodes; timing jitter; 5 W; 750 to 850 nm; 79.3 MHz; ORION photoinjector drive laser oscillator subsystem; ORION photoinjector laser oscillator pulse train; RF reference input; S-Band photoinjector; S-band 36th harmonic; Spectra-Physics Tsunami ultrafast tunable laser; external photodiode RF output; laser oscillator generated noise; laser oscillator generated transfer function; timing jitter measurements; ultra low noise crystal rf oscillator; Laser excitation; Laser noise; Laser tuning; Noise measurement; Optical pulses; Oscillators; Pulse measurements; Pump lasers; Radio frequency; Timing jitter;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
ISSN
1063-3928
Print_ISBN
0-7803-7738-9
Type
conf
DOI
10.1109/PAC.2003.1288796
Filename
1288796
Link To Document