Title :
Automation of a mass spectrometer and extraction line for the determination of noble gas isotopes in rocks
Author :
Singer, R. ; Curtice, J. ; Kurz, M. ; Lott, D., III
Author_Institution :
Woods Hole Oceanogr. Instn., MA, USA
Abstract :
This paper describes the automation of an extraction line and mass spectrometer for the determination of noble gas isotope concentrations in rock and mineral samples, housed in the Isotope Geochemistry Facility at Woods Hole Oceanographic Institution (WHOI). The gas extraction occurs in an automated ultra-high-vacuum system designed and fabricated at WHOI. The noble gases of interest are extracted in vacuo by crushing or high temperature fusion, separated using a cryogenic charcoal trap (operated between 70 and 3000 K), and delivered to a Mass Analyzer Products 215-50 mass spectrometer for measurement of isotopic composition. The system is controlled by a PC running under the Windows NT operating system. The software, largely written in Visual Basic and developed at WHOI, provides for synchronization of the extraction process with the mass spectrometer measurements. The extraction line control software is written so that the user can easily modify and customize the procedures, and allows automated operation. The extraction line software also provides a test scheduler, with building blocks which allow control of the system hardware by the computer without programming for modification and extension of the system by the operators. Software on a second PC controls the operation of the mass spectrometer over an IEEE-488 (GPIB) bus. This code was modified at WHOI to provide for the synchronization of the mass spectrometer with the extraction line and to optimize the determination of the measured gas concentrations. The system is primarily used to make helium and neon isotope measurements, in full 24 hour automation mode, but has also been designed and tested for Ar and Xe isotopes. This system is devoted to the measurement of both mantle and cosmic-ray-produced noble gas isotopes
Keywords :
geochemistry; geophysical equipment; inert gases; isotope relative abundance; mass spectroscopic chemical analysis; oceanographic equipment; Isotope Geochemistry Facility; WHOI; Woods Hole Oceanographic Institution; automation; chemical analysis; extraction line; gas extraction; geochemistry; geophysical equipment; inert gas; isotope ratio; isotopic composition; mass spectrometer; mass spectroscopy; mineral sample; noble gas; ocean; rock; test scheduler; Automatic control; Automation; Control systems; Gases; Isotopes; Mass spectroscopy; Minerals; Ocean temperature; Sea measurements; System testing;
Conference_Titel :
OCEANS 2000 MTS/IEEE Conference and Exhibition
Conference_Location :
Providence, RI
Print_ISBN :
0-7803-6551-8
DOI :
10.1109/OCEANS.2000.881244