DocumentCode
3595549
Title
Preliminary validation and performance of the Jason microwave radiometer
Author
Brown, Shannon ; Ruf, Chris ; Keihm, Steve ; Kitiyakara, Ami
Author_Institution
Michigan Univ., Ann Arbor, MI, USA
Volume
2
fYear
2003
Firstpage
1077
Abstract
The Jason microwave radiometer is calibrated using hot and cold on-Earth theoretical brightness temperature references. The retrieved path delay values are validated using collocated Topex microwave radiometers and radiosonde values. The calibrated path delay values are demonstrated to have no significant bias or scale errors. The absolute accuracy of the individual path delay values is demonstrated to have no significant bias or scale errors. The absolute accuracy of the individual path delay measurement exceeds the mission goal of 1.2 cm RMS.
Keywords
calibration; geophysical techniques; microwave measurement; radiometers; remote sensing; JMR; Jason microwave radiometer; TMR; Topex microwave radiometers; calibrated path delay; calibration; on-Earth theoretical brightness temperature references; performance evaluation; radiosonde values; satellite; scale errors; Brightness temperature; Calibration; Delay; Extraterrestrial measurements; Frequency; Instruments; Microwave radiometry; Ocean temperature; Satellite broadcasting; Sea measurements;
fLanguage
English
Publisher
ieee
Conference_Titel
Geoscience and Remote Sensing Symposium, 2003. IGARSS '03. Proceedings. 2003 IEEE International
Print_ISBN
0-7803-7929-2
Type
conf
DOI
10.1109/IGARSS.2003.1294016
Filename
1294016
Link To Document