DocumentCode
3595737
Title
Monte Carlo investigation of the charge sharing effects in 3-D position sensitive CdZnTe gamma ray spectrometers
Author
Du, Y.F. ; He, Z. ; Li, W. ; Knoll, G.F. ; Wehe, D.K.
Author_Institution
Dept. of Nucl. Eng. & Radiol. Sci., Michigan Univ., Ann Arbor, MI, USA
Volume
1
fYear
1998
fDate
6/20/1905 12:00:00 AM
Firstpage
634
Abstract
Charge sharing effects in a 3-D position sensitive CdZnTe detector have been investigated by Monte Carlo simulations and experimental measurements. The charge sharing is mainly caused by the range of electrons, X-ray emission following by photoelectric interactions, and the diffusion of charge carrier electrons during their drift towards the anodes. A simple model has been developed to include the diffusion effect in the Monte Carlo simulation. Good agreement has been achieved for various irradiation and bias conditions. Based on our model simulations, a 1 mm optimal pixel size is recommended for future 1 cm thick CZT detectors for 662 keV gamma rays
Keywords
Monte Carlo methods; diffusion; gamma-ray spectrometers; position sensitive particle detectors; semiconductor counters; 1 mm; 662 keV; CdZnTe; CdZnTe gamma ray spectrometers; Monte Carlo; X-ray emission; bias; charge sharing; electron diffusion; irradiation; photoelectric; pixel size; position sensitive; Anodes; Charge carriers; Charge measurement; Current measurement; Electron emission; Gamma ray detection; Gamma ray detectors; Monte Carlo methods; Position measurement; Position sensitive particle detectors;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE
ISSN
1082-3654
Print_ISBN
0-7803-5021-9
Type
conf
DOI
10.1109/NSSMIC.1998.775219
Filename
775219
Link To Document