• DocumentCode
    3596629
  • Title

    An experimental study on current vs. temperature effect of gold ribbon for wire bonding in power devices

  • Author

    Prabhu, Shreesha ; Koyili, Sankaran ; Manjunath, M.S. ; Nayak, M.M.

  • Author_Institution
    MIT, Manipal, India
  • fYear
    2014
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Wire Bonding is a well known method used for interconnecting integrated circuit (IC) die and the leads of its package. In this paper, the effect of current on the temperature of the gold (Au) ribbon used for wire bonding in the packaging of power device is presented. Infrared spectrometer study and direct thin film Pt temperature sensor analysis were used to analyze the temperature variations in gold ribbon.
  • Keywords
    gold; infrared spectrometers; integrated circuit interconnections; integrated circuit packaging; lead bonding; platinum; power integrated circuits; temperature sensors; thin films; Au; IC die; Pt; current effect; direct thin film; gold ribbon; infrared spectrometer; integrated circuit interconnection; platinum temperature sensor analysis; power device package; temperature effect; wire bonding; Bonding; Current measurement; Encapsulation; Gold; Temperature measurement; Temperature sensors; Wires; Gold Ribbon; Temperature Behavior; Wire Bonding;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Emerging Electronics (ICEE), 2014 IEEE 2nd International Conference on
  • Print_ISBN
    978-1-4673-6527-7
  • Type

    conf

  • DOI
    10.1109/ICEmElec.2014.7151206
  • Filename
    7151206