    Long-term geometry stability of ATLAS MDT chambers studied with a high-precision X-ray tomograph

  • Author

    Schuh, Silvia ; Kowarik, Gregor ; Marchesotti, Marco ; Da Silva, Ricardo ; Voss, R?¼diger ; Zhuravlov, Vadym

  • Author_Institution
    Dept. of Phys., CERN, Geneva, Switzerland
  • Volume
    2
  • fYear
    2005
  • Firstpage
    1024
  • Lastpage
    1028
  • Abstract
    The CERN X-ray tomograph measures the 2-dimensional position of MDT chamber wires with a total uncertainty of less than 5 microns. This dedicated facility has assured consistent production quality of chamber geometries over the five year construction phase between 2000 and 2005 by sampling about 15% of the total 1200 MDT chambers produced. Part of the tomograph measurement capacity has been used to perform re-measurements of selected chambers. We briefly describe the tomograph facility and its capabilities, present a global view of the mechanical accuracy and consistency of the full MDT production and then summarize the results obtained from the chamber re-measurements and discuss their possible implications for long-term MDT geometry stability.
  • Keywords
    X-ray absorption; drift chambers; position measurement; tomography; 2-dimensional MDT chamber position; ATLAS MDT chambers; MDT production; high-precision CERN X-ray tomograph; long-term MDT geometry stability; monitored drift tube chambers; tomograph facility; Geometry; Large Hadron Collider; Mesons; Physics; Production; Spectroscopy; Stability; Strips; Toroidal magnetic fields; Wires;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2005 IEEE
  • ISSN
    1095-7863
  • Print_ISBN
    0-7803-9221-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2005.1596427
  • Filename
    1596427