• DocumentCode
    3602008
  • Title

    Epipolar Consistency in Transmission Imaging

  • Author

    Aichert, Andre ; Berger, Martin ; Jian Wang ; Maass, Nicole ; Doerfler, Arnd ; Hornegger, Joachim ; Maier, Andreas K.

  • Author_Institution
    Pattern Recognition Lab., Friedrich-Alexander-Univ. Erlangen-Nuremberg, Erlangen, Germany
  • Volume
    34
  • Issue
    11
  • fYear
    2015
  • Firstpage
    2205
  • Lastpage
    2219
  • Abstract
    This paper presents the derivation of the Epipolar Consistency Conditions (ECC) between two X-ray images from the Beer-Lambert law of X-ray attenuation and the Epipolar Geometry of two pinhole cameras, using Grangeat´s theorem. We motivate the use of Oriented Projective Geometry to express redundant line integrals in projection images and define a consistency metric, which can be used, for instance, to estimate patient motion directly from a set of X-ray images. We describe in detail the mathematical tools to implement an algorithm to compute the Epipolar Consistency Metric and investigate its properties with detailed random studies on both artificial and real FD-CT data. A set of six reference projections of the CT scan of a fish were used to evaluate accuracy and precision of compensating for random disturbances of the ground truth projection matrix using an optimization of the consistency metric. In addition, we use three X-ray images of a pumpkin to prove applicability to real data. We conclude, that the metric might have potential in applications related to the estimation of projection geometry. By expression of redundancy between two arbitrary projection views, we in fact support any device or acquisition trajectory which uses a cone-beam geometry. We discuss certain geometric situations, where the ECC provide the ability to correct 3D motion, without the need for 3D reconstruction.
  • Keywords
    biomedical equipment; computerised tomography; diagnostic radiography; medical image processing; optimisation; stereo image processing; 3D motion; Beer-Lambert law; CT scan; FDCT data; Grangeat´s theorem; X-ray attenuation; X-ray imaging; acquisition trajectory device; arbitrary projection views; cone-beam geometry; epipolar consistency conditions; epipolar consistency metric; epipolar geometry; ground truth projection matrix; oriented projective geometry; patient motion; pinhole cameras; projection geometry estimation; projection imaging; pumpkin; transmission imaging; Cameras; Detectors; Geometry; Measurement; Three-dimensional displays; Transforms; X-ray imaging; X-ray tomography; X-rays; geometry; motion estimation; stereo vision;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2015.2426417
  • Filename
    7094279