DocumentCode
3603052
Title
Measurement Issues in Galvanic Intrabody Communication: Influence of Experimental Setup
Author
Amparo Callejon, M. ; Reina-Tosina, Javier ; Naranjo-Hernandez, David ; Roa, Laura M.
Author_Institution
CIBER de Bioingenieria, Biomater. y Nanomedicina, Univ. of Seville, Seville, Spain
Volume
62
Issue
11
fYear
2015
Firstpage
2724
Lastpage
2732
Abstract
Significance: The need for increasingly energy-efficient and miniaturized bio-devices for ubiquitous health monitoring has paved the way for considerable advances in the investigation of techniques such as intrabody communication (IBC), which uses human tissues as a transmission medium. However, IBC still poses technical challenges regarding the measurement of the actual gain through the human body. The heterogeneity of experimental setups and conditions used together with the inherent uncertainty caused by the human body make the measurement process even more difficult. Goal: The objective of this study, focused on galvanic coupling IBC, is to study the influence of different measurement equipments and conditions on the IBC channel. Methods : Different experimental setups have been proposed in order to analyze key issues such as grounding, load resistance, type of measurement device and effect of cables. In order to avoid the uncertainty caused by the human body, an IBC electric circuit phantom mimicking both human bioimpedance and gain has been designed. Given the low-frequency operation of galvanic coupling, a frequency range between 10 kHz and 1 MHz has been selected. Results : The correspondence between simulated and experimental results obtained with the electric phantom have allowed us to discriminate the effects caused by the measurement equipment. Conclusion: This study has helped us obtain useful considerations about optimal setups for galvanic-type IBC as well as to identify some of the main causes of discrepancy in the literature.
Keywords
bioelectric phenomena; biological tissues; biomedical equipment; biomedical measurement; phantoms; IBC electric circuit phantom; electric phantom; energy-efficient-miniaturized biodevices; frequency 10 kHz to 1 MHz; galvanic coupling IBC; galvanic intrabody communication; human bioimpedance; human body; human tissues; inherent uncertainty; low-frequency operation; measurement equipment; transmission medium; ubiquitous health monitoring; Biomedical measurement; Couplings; Electrical resistance measurement; Gain measurement; Immune system; Integrated circuit modeling; Voltage measurement; Electric circuit phantom; experimental setup; gain; galvanic coupling; grounding; intrabody communication; load resistance;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/TBME.2015.2444916
Filename
7123179
Link To Document