DocumentCode
3603365
Title
Automated, Depth-Resolved Estimation of the Attenuation Coefficient From Optical Coherence Tomography Data
Author
Smith, Gennifer T. ; Dwork, Nicholas ; O´Connor, Daniel ; Sikora, Uzair ; Lurie, Kristen L. ; Pauly, John M. ; Ellerbee, Audrey K.
Author_Institution
Dept. of Electr. Eng., Stanford Univ., Stanford, CA, USA
Volume
34
Issue
12
fYear
2015
Firstpage
2592
Lastpage
2602
Abstract
We present a method for automated, depth-resolved extraction of the attenuation coefficient from Optical Coherence Tomography (OCT) data. In contrast to previous automated, depth-resolved methods, the Depth-Resolved Confocal (DRC) technique derives an invertible mapping between the measured OCT intensity data and the attenuation coefficient while considering the confocal function and sensitivity fall-off, which are critical to ensure accurate measurements of the attenuation coefficient in practical settings (e.g., clinical endoscopy). We also show that further improvement of the estimated attenuation coefficient is possible by formulating image denoising as a convex optimization problem that we term Intensity Weighted Horizontal Total Variation (iwhTV). The performance and accuracy of DRC alone and DRC+iwhTV are validated with simulated data, optical phantoms, and ex-vivo porcine tissue. Our results suggest that implementation of DRC+iwhTV represents a novel way to improve OCT contrast for better tissue characterization through quantitative imaging.
Keywords
biological tissues; biomedical optical imaging; image denoising; medical image processing; optical tomography; phantoms; OCT contrast; OCT intensity data; attenuation coefficient; automated depth-resolved estimation; clinical endoscopy; convex optimization problem; depth-resolved confocal technique; ex-vivo porcine tissue; image denoising; intensity weighted horizontal total variation; invertible mapping; optical coherence tomography data; optical phantoms; quantitative imaging; Attenuation; Convex functions; Noise reduction; Optical attenuators; Signal to noise ratio; Tomography; Attenuation coefficient; confocal function; convex optimization; optical coherence tomography;
fLanguage
English
Journal_Title
Medical Imaging, IEEE Transactions on
Publisher
ieee
ISSN
0278-0062
Type
jour
DOI
10.1109/TMI.2015.2450197
Filename
7134771
Link To Document