DocumentCode :
3603414
Title :
The Influence of Transposition Angle on 3-D Global Domain Magnetic Field of Stator Bar in Water-Cooled Turbo-Generator
Author :
Yanping Liang ; Lei Wu ; Xu Bian ; Honghao Yu
Author_Institution :
Sch. of Electr. & Electron. Eng., Harbin Univ. of Sci. & Technol., Harbin, China
Volume :
51
Issue :
11
fYear :
2015
Firstpage :
1
Lastpage :
4
Abstract :
Reasonable transposition structure of stator bars in water-cooled turbo-generators could reduce circulating current of strands, and related factors on distribution change of circulating current are complex and diverse. Transposition angle is one of the most important influencing factors, and its influencing degree on circulating current is still unclear. A 600 MW water-cooled turbo-generator is set as an example, a 3-D physical model of transposition bars in a single slot is established, and a field-circuit coupling method is used in 3-D numerical calculation. The optimization of transposition angle is researched, and the distribution changes of 3-D global domain magnetic field, maximum current, and circulating current loss in different transposition angles are obtained. Finally, the calculation results are compared with that of the improved analytical algorithm to validate the accuracy of the solving model.
Keywords :
magnetic fields; optimisation; stators; turbogenerators; 3-D global domain magnetic field; circulating current; field-circuit coupling method; maximum current; reasonable transposition structure; stator bar; transposition angle; water-cooled turbo-generator; Bars; Magnetic fields; Magnetic flux density; Mathematical model; Numerical models; Stator bars; Circulating current; Magnetic field; magnetic field; numerical calculation; transposition angle; water-cooled turbo-generator;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.2015.2450932
Filename :
7138639
Link To Document :
بازگشت