Title :
Power Quality Improvement in Isolated Distributed Power Generating System Using DSTATCOM
Author :
Arya, Sabha Raj ; Niwas, Ram ; Bhalla, Krishan Kant ; Singh, Bhim ; Chandra, Ambrish ; Al-Haddad, Kamal
Author_Institution :
Dept. of Electr. Eng., Indian Inst. of Technol. Delhi, New Delhi, India
Abstract :
This paper presents the control of a synchronous reluctance generator (SyRG) driven by a biogas/biomass diesel engine as a prime mover in a distributed power generating system. This generator is used as a source to feed linear and nonlinear loads. A three-leg voltage source converter (VSC)-based distribution static compensator (DSTATCOM) is implemented using an adaptive neural network-based control algorithm for harmonic suppression, load balancing, and voltage regulation in a three-phase SyRG system with a battery energy storage system. This control algorithm is used for extraction of active and reactive power components of distorted load currents. These components of load currents are used for estimation of reference source currents to generate the gating pulses of VSC used as DSTATCOM. The performance of DSTATCOM is observed satisfactory for this type of power generating system under balanced and unbalanced loads.
Keywords :
adaptive control; diesel engines; distributed power generation; machine control; neural nets; power convertors; power supply quality; power system harmonics; reactive power; reluctance generators; static VAr compensators; voltage control; DSTATCOM; VSC; adaptive neural network-based control algorithm; battery energy storage system; biogas-biomass diesel engine; distribution static compensator; harmonic suppression; isolated distributed power generating system; load balancing; load currents; power quality improvement; reactive power components; reference source currents; synchronous reluctance generator; three-leg voltage source converter; three-phase SyRG system; voltage regulation; Adaptive systems; Batteries; Generators; Harmonic analysis; Power quality; Reactive power; Voltage control; Biogas/Biomass diesel engine; Biogas/biomass diesel engine; Harmonic suppression; Load balancing; Power quality; Voltage regulation; harmonic suppression; load balancing; power quality; synchronous reluctance generator; synchronous reluctance generator (SyRG); voltage regulation;
Journal_Title :
Industry Applications, IEEE Transactions on
DOI :
10.1109/TIA.2015.2451093