DocumentCode :
3604879
Title :
Development of an Immunosensor Based on Layered Double Hydroxides for MMR Cancer Biomarker Detection
Author :
Hammami, M. ; Soussou, A. ; Idoudi, F. ; Cohen-Bouhacina, T. ; Bouhaouala-Zahar, B. ; Baccar, Z.M.
Author_Institution :
Nanobioengineering Group, Nat. Inst. of Res. & Physiochem. Anal., Sidi-Thabet, Tunisia
Volume :
14
Issue :
7
fYear :
2015
Firstpage :
688
Lastpage :
693
Abstract :
As a potential biomarker for the investigation of cancer inflammatory profiles, macrophage mannose receptor (MMR, CD206) is herein selected to develop an immunosensor based on layered double hydroxide (LDH). Like an endocyte C-type lectin receptor, MMR plays an important role in immune homeostasis by scavenging unwanted mannose glycoproteins. It attracts a progressive attention thanks to its particularly high expression within the tumor microenvironment. There is a great of interest to develop an immunosensor based on an antibody specific to MMR for detection of stroma versus tumor cells. In this work, we studied the feasibility of high sensitive MMR cancer Screen Printed Electrode (SPE) immunosensor. Working electrode of commercialized SPE was modified by immobilization of specific antibody (anti-MMR) into thin layer of LDH nanomaterials. Structural, morphological, and surface properties of LDHs were studied by X-Ray diffraction, atomic force microscopy and Infrared spectroscopy in ATR. Cyclic Voltammetry technique was used to study interaction between the human recombinant MMR protein (rHu-MMR, NSO derived) and an immobilized antibody into developed immunosensor. High specific response of -11.72 μA/ng·mL-1 (with a correlation coefficient of R2=0.994) were obtained in linear range of 0.05 ng/mL to 10.0 ng/mL of specific recombinant antigen. The limit of detection (LOD) was less than 15.0 pg/mL. From these attractive results, the feasibility of an electrochemical immunosensor for cancer was proved. Additional experiments to study stability and reproducibility the immunosensor should be completed in perspective to use these anti-MMR based immunosensors for sensing human MMR in patient biopsies and sera.
Keywords :
X-ray diffraction; atomic force microscopy; biosensors; cancer; electrochemical electrodes; electrochemical sensors; infrared spectra; proteins; tumours; voltammetry (chemical analysis); CD206; MMR cancer biomarker detection; MMR cancer screen printed electrode immunosensor; X-Ray diffraction; atomic force microscopy; cancer inflammatory profile; cyclic voltammetry technique; electrochemical immunosensor; endocyte C-type lectin receptor; human recombinant MMR protein; immune homeostasis; immunosensor development; infrared spectroscopy; layered double hydroxide morphological properties; layered double hydroxide nanomaterial; layered double hydroxide sructural properties; layered double hydroxide surface properties; macrophage mannose receptor; mannose glycoprotein; tumor cell; tumor microenvironment; Cancer; Electrodes; Films; Immune system; Nanobioscience; Surface treatment; Tumors; Immunosensor; layered double hydroxide; macrophage mannose receptor; nanomaterials;
fLanguage :
English
Journal_Title :
NanoBioscience, IEEE Transactions on
Publisher :
ieee
ISSN :
1536-1241
Type :
jour
DOI :
10.1109/TNB.2015.2462025
Filename :
7219430
Link To Document :
بازگشت