• DocumentCode
    3606747
  • Title

    Small and Ultra-Small Angle X-Ray Scattering Contrast Obtained With a Synchrotron-Based Shack–Hartmann Imaging System

  • Author

    Wiebe, Sheldon ; Samadi, Nazanin ; Belev, George ; Martinson, Mercedes ; Bassey, Bassey ; Chapman, Dean

  • Author_Institution
    Dept. of Med. Imaging, R. Univ. Hosp., Saskatoon, SK, Canada
  • Volume
    62
  • Issue
    5
  • fYear
    2015
  • Firstpage
    2031
  • Lastpage
    2035
  • Abstract
    A number of phase based X-ray imaging methods have been developed that derive contrast from phase effects from the object which make them particularly interesting because of the ability to visualize soft tissues. Shack-Hartmann is a wave-front diagnostic technique that emerged from optics which uses ray-line beams (beamlets) to interrogate the differences in the wave-front across a beam can also be used for X-ray imaging applications with phase sensitivity. This method, which has been applied in the X-ray regime, is very simple in that it only requires a screen to prepare an array of beamlets that then pass through the object and are allowed to propagate a distance onto a pixelated detector. Absorption and refraction information can be extracted from the detected beamlets. An untapped property is the additional ability to extract scatter distribution information based on the observed width of the detected spots. This paper describes experiments done at a synchrotron facility investigating the use of a Shack-Hartmann system for biomedical applications and include our method and examples of scatter contrast extraction from the method.
  • Keywords
    X-ray scattering; absorption coefficients; biological tissues; biomedical equipment; biomedical optical imaging; diagnostic radiography; X-ray regime; absorption information; detected beamlets; phase based X-ray imaging methods; phase effects; phase sensitivity; pixelated detector; ray-line beams; refraction information; scatter contrast extraction; scatter distribution information; soft tissues; synchrotron facility; synchrotron-based Shack-Hartmann imaging system; ultrasmall angle X-ray scattering contrast; wave-front diagnostic technique; Absorption; Biomedical imaging; Detectors; Scattering; X-ray diffraction; X-ray imaging; Biomedical imaging; X-ray diffraction; X-rays; image analysis; synchrotron radiation;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2015.2470555
  • Filename
    7274368