DocumentCode :
3609409
Title :
Effect of oil replacement on furfural analysis and aging assessment of power transformers
Author :
Yuandi Lin ; Lijun Yang ; Ruijin Liao ; Weidong Sun ; Yiyi Zhang
Author_Institution :
State Key Lab. of Power Equip. & Syst. Security & New Technol., Chongqing Univ., Chongqing, China
Volume :
22
Issue :
5
fYear :
2015
fDate :
10/1/2015 12:00:00 AM
Firstpage :
2611
Lastpage :
2619
Abstract :
Furfural analysis is considered as a reliable method to estimate aging of cellulose insulation paper and is widely applied in assessing the condition of field transformers. However, the actual concentration of furfural in insulating oil is influenced by oil replacement, and the correction method is seldom studied. In this research, an accelerated thermal aging test of oil-paper samples was conducted at 130 °C for 35 days. Insulating oil was replaced at early, middle, and late aging stages to investigate furfural loss during the oil replacement process and its effects on assessing the aging of insulation paper. Results showed that furfural in oil obviously declined after oil replacement, which caused a severe error in paper aging evaluation. To correct furfural loss, the furfural correction factor, which is defined as the ratio of the furfural content in oil after oil replacement to the furfural content before oil replacement, was introduced into the furfural analysis method. The parameters and influencing factors of the furfural correction function were researched. The furfural correction function was verified using experimental data obtained under laboratory conditions and field data collected from 44 in-service transformers. The results showed that the furfural correction function effectively corrects furfural loss during oil replacement and improves the accuracy of estimating paper aging. Finally, the furfural correction function was extended to the operating conditions of field transformers.
Keywords :
paper; power transformer insulation; power transformer testing; reliability; transformer oil; aging estimation method reliability; cellulose insulation paper; field transformer operating condition assessment; furfural analysis method; furfural content; furfural correction factor; furfural correction function; furfural loss; in-service transformer; insulating oil; oil replacement effect; oil-paper sample accelerated thermal aging test; power transformer aging assessment; power transformer furfural analysis; temperature 130 degC; time 35 day; Aging; Degradation; Estimation; Oil insulation; Power transformer insulation; Furfural analysis; aging assessment; oil replacement; oil-paperinsulation; power transformer;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/TDEI.2015.005144
Filename :
7311036
Link To Document :
بازگشت