DocumentCode
3609436
Title
Electrical treeing behavior at high temperature in XLPE cable insulation samples
Author
Xiangrong Chen ; Yang Xu ; Xiaolong Cao ; Gubanski, S.M.
Author_Institution
Dept. of Mater. & Manuf. Technol., Chalmers Univ. of Technol., Goteborg, Sweden
Volume
22
Issue
5
fYear
2015
fDate
10/1/2015 12:00:00 AM
Firstpage
2841
Lastpage
2851
Abstract
This paper reports on investigations aiming to understand the behavior of electrical trees formed in XLPE cable insulation at elevated temperatures. Samples cut from a real high voltage cable equipped with an embedded electrode system and composed of a needle separated by 2 mm from counter electrode were used. The temperature was varied between 50 and 90 °C and the range of voltage changed between 9 and 18 kV. The electrical treeing process was followed by means of microscopic observation from the moment of initiation until the leading branches connected the counter electrode and partial discharge (PD) activity was monitored simultaneously. The shape and fractal dimension of the resulting trees were analyzed. It was found that temperature and voltage level had pronounced effect on the process of electrical tree formation. At lower voltages different type of trees could be formed, whereas at higher voltages branch trees dominated. Increase of test temperature reduced the time for tree initiation, whereas the tree growth time was less affected, except for the lowest voltage level at which the slowest tree development was observed at the highest test temperature. It is postulated that the impeding effect of elevated temperature on tree growth is due to a change of tree channel sidewall conductivity, whereas the observed reduction of tree initiation time with the increase of temperature and voltage level is attributed to lowering of the threshold energy for damage at higher temperature as well as increasing of the injection current at higher voltage level.
Keywords
XLPE insulation; power cable insulation; trees (electrical); PD activity; XLPE cable insulation samples; counter electrode; electrical treeing behavior; embedded electrode system; high voltage cable; injection current; partial discharge activity; threshold energy; tree channel sidewall conductivity; tree growth; tree initiation; Cable insulation; Electrodes; Needles; Partial discharges; Radiation detectors; Shape; Temperature measurement; Electrical treeing; XLPE cable insulation; growth time; high temperature; initiation time; partial discharge;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/TDEI.2015.004784
Filename
7311063
Link To Document