  • Title

    Capacitance-Based Dosimetry of Co-60 Radiation Using Fully-Depleted Silicon-on-Insulator Devices

  • Author

    Yulong Li ; Porter, Warren M. ; Ma, Rui ; Reynolds, Margaret A. ; Gerbi, Bruce J. ; Koester, Steven J.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of Minnesota, Minneapolis, MN, USA
  • Volume
    62
  • Issue
    6
  • fYear
    2015
  • Firstpage
    3012
  • Lastpage
    3019
  • Abstract
    The capacitance-based sensing of fully-depleted silicon-on-insulator (FDSOI) variable capacitors for Co-60 gamma radiation is investigated. Linear response of the capacitance is observed for radiation dose up to 64 Gy, while the percent capacitance change per unit dose is as high as 0.24%/Gy. An analytical model is developed to study the operational principles of the varactors and the maximum sensitivity as a function of frequency is determined. The results show that FDSOI varactor dosimeters have potential for extremely-high sensitivity as well as the potential for high frequency operation in applications such as wireless radiation sensing.
  • Keywords
    cobalt; dosimetry; gamma-rays; radiation effects; silicon-on-insulator; varactors; Co; FDSOI varactor dosimeters; Si; capacitance-based dosimetry; capacitance-based sensing; fully-depleted silicon-on-insulator devices; gamma radiation; linear response; radiation dose; wireless radiation sensing; Capacitance; Dosimetry; MOS devices; Radiation detectors; Radiation effects; Sensitivity; Silicon-on-insulator; Varactors; Dosimeters; MOS devices; SOI; radiation detectors; varactors;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2015.2487239
  • Filename
    7322297