DocumentCode :
3609985
Title :
Capacitance-Based Dosimetry of Co-60 Radiation Using Fully-Depleted Silicon-on-Insulator Devices
Author :
Yulong Li ; Porter, Warren M. ; Ma, Rui ; Reynolds, Margaret A. ; Gerbi, Bruce J. ; Koester, Steven J.
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of Minnesota, Minneapolis, MN, USA
Volume :
62
Issue :
6
fYear :
2015
Firstpage :
3012
Lastpage :
3019
Abstract :
The capacitance-based sensing of fully-depleted silicon-on-insulator (FDSOI) variable capacitors for Co-60 gamma radiation is investigated. Linear response of the capacitance is observed for radiation dose up to 64 Gy, while the percent capacitance change per unit dose is as high as 0.24%/Gy. An analytical model is developed to study the operational principles of the varactors and the maximum sensitivity as a function of frequency is determined. The results show that FDSOI varactor dosimeters have potential for extremely-high sensitivity as well as the potential for high frequency operation in applications such as wireless radiation sensing.
Keywords :
cobalt; dosimetry; gamma-rays; radiation effects; silicon-on-insulator; varactors; Co; FDSOI varactor dosimeters; Si; capacitance-based dosimetry; capacitance-based sensing; fully-depleted silicon-on-insulator devices; gamma radiation; linear response; radiation dose; wireless radiation sensing; Capacitance; Dosimetry; MOS devices; Radiation detectors; Radiation effects; Sensitivity; Silicon-on-insulator; Varactors; Dosimeters; MOS devices; SOI; radiation detectors; varactors;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2015.2487239
Filename :
7322297
Link To Document :
بازگشت