DocumentCode
3610429
Title
Turn–turn short circuit fault management in permanent magnet machines
Author
Arumugam, Puvan ; Hamiti, Tahar ; Gerada, Chris
Author_Institution
Power Electron. Machines & Control Group, Univ. of Nottingham, Nottingham, UK
Volume
9
Issue
9
fYear
2015
Firstpage
634
Lastpage
641
Abstract
This study presents a systematic study on turn-turn short circuit (SC) fault and ways to manage them to provide a basis for comparison of the various options available. The possible methods to reduce the likelihood of the winding SC fault and the fault mitigation techniques related to such faults are discussed. A finite-element analysis of a surface-mounted permanent magnet machine under application of different mitigation techniques during a turn-turn fault is presented. Both machine and drive structural adaptations for different fault mitigation techniques are addressed. Amongst the investigated fault mitigation techniques, the most promising solution is identified and validated experimentally. It is shown that the shorting terminal method adopting vertical winding arrangement is an effective method in terms of the implementation, reliability and weight.
Keywords
finite element analysis; machine windings; permanent magnet machines; short-circuit currents; surface mount technology; fault mitigation technique; finite element analysis; reliability; shorting terminal method; surface mounted permanent magnet machine; turn-turn short circuit fault management; winding arrangement;
fLanguage
English
Journal_Title
Electric Power Applications, IET
Publisher
iet
ISSN
1751-8660
Type
jour
DOI
10.1049/iet-epa.2015.0020
Filename
7328478
Link To Document