DocumentCode :
3611512
Title :
On-line fault monitoring system for hydroelectric generators based on spectrum analysis of the neutral current
Author :
Rami?Œ??rez-Ni?ƒ?±o, Jose?Œ?? ; Pascacio, Alberth ; Mijarez, Rito ; Rodri?Œ??guez-Rodri?Œ??guez, Joaqui?Œ??n
Author_Institution :
Inst. de Investig. Electr., Cuernavaca, Mexico
Volume :
9
Issue :
16
fYear :
2015
Firstpage :
2509
Lastpage :
2516
Abstract :
An on-line fault monitoring diagnostic system for hydroelectric generators based on spectrum analysis of neutral current is presented. Hydroelectric generators are fundamental elements in the power train at hydroelectric power plants and require an adequate diagnostic analysis. Unexpected generator failures can lead to a significant financial effect owing to the elevated costs of emergency repairs and lost revenues caused by forced outage extended periods. Determining the actual operating conditions of a generator is a crucial phase in assessing the risk of failures. The on-line instrumentation fault monitoring diagnostic system uses a simplified electrical model of fault simulation in order to help interpret the harmonic sources in the neutral current. Field measurement results proved that the spectrum analysis model for detecting mechanical faults is effective.
Keywords :
condition monitoring; fault diagnosis; hydroelectric generators; reliability; risk management; spectral analysis; diagnostic analysis; fault monitoring diagnostic system; fault simulation; forced outage extended periods; generator failures; harmonic sources; hydroelectric generators; hydroelectric power plants; lost revenues; mechanical faults detection; neutral current; online fault monitoring diagnostic system; online fault monitoring system; power train; risk assessment; spectrum analysis;
fLanguage :
English
Journal_Title :
Generation, Transmission Distribution, IET
Publisher :
iet
ISSN :
1751-8687
Type :
jour
DOI :
10.1049/iet-gtd.2014.1136
Filename :
7337574
Link To Document :