DocumentCode
3611895
Title
Evaluation and Application of U.S. Medical Proton Facilities for Single Event Effects Test
Author
Wie, Brian S. ; LaBel, Kenneth A. ; Turflinger, Thomas L. ; Wert, Jerry L. ; Foster, Charles C. ; Reed, Robert A. ; Kostic, Andrew D. ; Moss, Steven C. ; Guertin, Steven M. ; George, Jeffrey S. ; Pankuch, Mark ; Dong, Lei ; Bloch, Charles ; Laub, Steve
Author_Institution
Integrity Applic. Inc., Chantilly, VA, USA
Volume
62
Issue
6
fYear
2015
Firstpage
2490
Lastpage
2497
Abstract
We present the challenges of using new medical proton therapy cyclotrons for SEE tests in the 200 MeV regime. Solutions are discussed to utilize these facilities as a replacement for the Indiana University Cyclotron Facility. Part data response to conventional scattered proton beams are compared to newer scanning beam configurations. A common dosimetry system for independent determination of fluence and beam uniformity is presented.
Keywords
cyclotrons; dosimetry; radiation therapy; Indiana University Cyclotron Facility; U.S. medical proton facilities application; U.S. medical proton facilities evaluation; beam uniformity; dosimetry system; medical proton therapy cyclotron; scanning beam configuration; scattered proton beam; single event effects test; Cyclotrons; Dosimetry; Particle beams; Radiation hardening (electronics); Dosimetry; proton beams; radiation hardness assurance; single event effects;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.2015.2496329
Filename
7348801
Link To Document