• DocumentCode
    3611978
  • Title

    Convex array vector velocity imaging using transverse oscillation and its optimization

  • Author

    Jensen, J?ƒ?¸rgen Arendt ; Brandt, Andreas Hjelm ; Nielsen, Michael Bachmann

  • Author_Institution
    Dept. of Electr. Eng., Tech. Univ. of Denmark, Lyngby, Denmark
  • Volume
    62
  • Issue
    12
  • fYear
    2015
  • fDate
    12/1/2015 12:00:00 AM
  • Firstpage
    2043
  • Lastpage
    2053
  • Abstract
    A method for obtaining vector flow images using the transverse oscillation (TO) approach on a convex array is presented. The paper presents optimization schemes for TO fields and evaluates their performance using simulations and measurements with an experimental scanner. A 3-MHz 192-element convex array probe (pitch 0.33 mm) is used in both simulations and measurements. A parabolic velocity profile is simulated at a beam-to-flow angle of 90°. The optimization routine changes the lateral oscillation period λx as a function of depth to yield the best possible estimates based on the energy ratio between positive and negative spatial frequencies in the ultrasound field. The energy ratio is reduced from -17.1 dB to -22.1 dB. Parabolic profiles are estimated on simulated data using 16 emissions. The optimization gives a reduction in standard deviation from 8.81% to 7.4% for 16 emissions, with a reduction in lateral velocity bias from -15.93% to 0.78% at 90° (transverse flow) at a depth of 40 mm. Measurements have been performed using the experimental ultrasound scanner and a convex array transducer. A bias of -0.93% was obtained at 87° for a parabolic velocity profile along with a standard deviation of 6.37%. The livers of two healthy volunteers were scanned using the experimental setup. The in vivo images demonstrate that the method yields realistic estimates with a consistent angle and mean velocity across three heart cycles.
  • Keywords
    biomedical transducers; biomedical ultrasonics; cardiology; optimisation; ultrasonic imaging; ultrasonic transducers; 192-element convex array probe; beam-flow angle; convex array transducer; convex array vector velocity imaging; frequency 3 MHz; in vivo imaging; lateral oscillation period; lateral velocity bias; mean velocity; optimization; optimization routine changes; parabolic velocity profile; simulated data; standard deviation; transverse oscillation approach; ultrasound scanner; vector flow imaging; Arrays; Focusing; Frequency measurement; Optimization; Oscillators; Transducers;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2015.006970
  • Filename
    7348979