DocumentCode :
3614326
Title :
Evaluation of an electronic ballast circuit for HID lamps with passive power factor correction
Author :
C. Branas;F.J. Azcondo;S. Bracho
Author_Institution :
Dept. of Electron. Technol., Syst. Eng. & Autom., Cantabria Univ., Santander, Spain
Volume :
1
fYear :
2002
fDate :
6/24/1905 12:00:00 AM
Firstpage :
371
Abstract :
This paper evaluates a new design of electronic ballast using the standard EN61000-2-3 and the recommended crest factor of the lamp current as references. The solution under study is based on a DC to AC resonant inverter whose input voltage is taken from a valley-fill AC-DC passive converter. The DC output of the valley fill circuit has a ripple of 50%. The output power dependence on the input voltage makes necessary an active compensation technique to stabilise the lamp power. Experimental results prove that the proposed solution is suitable to achieve high efficiency and low cost electronic ballast for low-medium power lamps.
Keywords :
"High intensity discharge lamps","Electronic ballasts","Circuits","Power factor correction","Voltage","Costs","Capacitors","Frequency conversion","Power harmonic filters","Resonant inverters"
Publisher :
ieee
Conference_Titel :
IECON 02 [Industrial Electronics Society, IEEE 2002 28th Annual Conference of the]
Print_ISBN :
0-7803-7474-6
Type :
conf
DOI :
10.1109/IECON.2002.1187537
Filename :
1187537
Link To Document :
بازگشت