DocumentCode :
36189
Title :
Subjective Evaluation of a Semi-Automatic Optical See-Through Head-Mounted Display Calibration Technique
Author :
Moser, Kenneth ; Itoh, Yuta ; Oshima, Kohei ; Swan, J. Edward ; Klinker, Gudrun ; Sandor, Christian
Author_Institution :
Dept. of Comput. Sci. & Eng., Mississippi State Univ., Starkville, MS, USA
Volume :
21
Issue :
4
fYear :
2015
fDate :
April 18 2015
Firstpage :
491
Lastpage :
500
Abstract :
With the growing availability of optical see-through (OST) head-mounted displays (HMDs) there is a present need for robust, uncomplicated, and automatic calibration methods suited for non-expert users. This work presents the results of a user study which both objectively and subjectively examines registration accuracy produced by three OST HMD calibration methods: (1) SPAAM, (2) Degraded SPAAM, and (3) Recycled INDICA, a recently developed semi-automatic calibration method. Accuracy metrics used for evaluation include subject provided quality values and error between perceived and absolute registration coordinates. Our results show all three calibration methods produce very accurate registration in the horizontal direction but caused subjects to perceive the distance of virtual objects to be closer than intended. Surprisingly, the semi-automatic calibration method produced more accurate registration vertically and in perceived object distance overall. User assessed quality values were also the highest for Recycled INDICA, particularly when objects were shown at distance. The results of this study confirm that Recycled INDICA is capable of producing equal or superior on-screen registration compared to common OST HMD calibration methods. We also identify a potential hazard in using reprojection error as a quantitative analysis technique to predict registration accuracy. We conclude with discussing the further need for examining INDICA calibration in binocular HMD systems, and the present possibility for creation of a closed-loop continuous calibration method for OST Augmented Reality.
Keywords :
augmented reality; calibration; helmet mounted displays; OST HMD calibration method; augmented reality; binocular HMD system; closed-loop continuous calibration method; degraded SPAAM; hazard; quality value assessment; quantitative analysis technique; recycled INDICA; semiautomatic optical see-through head-mounted display calibration technique; Accuracy; Calibration; Cameras; Hardware; Head; Visualization; Calibration; INDICA; OST HMD; SPAAM; eye tracking; user study;
fLanguage :
English
Journal_Title :
Visualization and Computer Graphics, IEEE Transactions on
Publisher :
ieee
ISSN :
1077-2626
Type :
jour
DOI :
10.1109/TVCG.2015.2391856
Filename :
7021939
Link To Document :
بازگشت