DocumentCode :
3619945
Title :
Reduction of vibration-induced errors in 3D measurement systems with vision and structured light
Author :
C.A. Luna;M. Mazo;J.L. Lazaro;J.F. Vazquez;J. Urena;J.J. Garcia;H. Sarmiento
Author_Institution :
Dept. of Electron., Alcala Univ., Madrid, Spain
Volume :
3
fYear :
2005
fDate :
6/27/1905 12:00:00 AM
Firstpage :
1291
Abstract :
In a 3D measurement system (3DMS) using triangulation and vision (i.e. laser and camera), it is necessary to know, with high precision, the rotation angles of the camera and the laser with respect to the object on which the 3D-coordinate measurements are desired. A small variation of these angles causes significant errors. In a previous work, to measure the rotation angle variations of the camera and the laser under vibrations, a system that uses two area cameras and two artificial marks were presented. In this work, a new solution based on a sensor with two line scans and two artificial marks are proposed. The models and procedures to achieve the measurement of the rotation angles of the camera and the laser, as well as the results obtained after simulations, are also presented.
Keywords :
"Vibration measurement","Machine vision","Cameras","Rotation measurement","Wires","Velocity measurement","Coordinate measuring machines","Area measurement","Goniometers","Laser modes"