Title :
Precise measurements of quartz crystal units by network analyzer technique applied to two different types of test jig
Author :
V.P. Popovic-Milovanovic;B.J. Dobnikar;V.L. Popovic
Author_Institution :
Inst. Mihajlo Pupin, Belgrade, Yugoslavia
fDate :
6/10/1905 12:00:00 AM
Abstract :
The accuracy and repeatability of the quartz crystal parameter measurement method are investigated using network analyzer techniques applied to two different types of test jigs, coaxial and Pi-network, under controlled temperature conditions. The accuracy and repeatability are presented as a function of frequency, for these types of test jigs. The results are in good agreement with those obtained using the reference method.
Keywords :
"Frequency measurement","Velocity measurement","Time measurement","Testing","Scattering parameters","Fixtures","IEC standards","Measurement units","Frequency estimation","Error correction"
Conference_Titel :
Frequency Control Symposium, 1988., Proceedings of the 42nd Annual
DOI :
10.1109/FREQ.1988.27640