Continuous Gain Calibration of Parallel Delta Sigma A/D Converters
Author :
Alma Delic-Ibukic;Donald M. Hummels
Author_Institution :
Department of Electrical and Computer Engineering, University of Maine, 5708 Barrows Hall, Orono, ME 04469-5708, USA
fYear :
2006
fDate :
4/1/2006 12:00:00 AM
Firstpage :
905
Lastpage :
909
Abstract :
A method to correct for gain errors in each channel of a parallel delta-sigma (PiDeltaSigma) converters in real-time is presented. The calibration technique requires an additional channel that is linearly dependant on PiDeltaSigma channels used. By introducing the redundancy in a system, the adaptive LMS algorithm can be used to correct for gain errors within the channels. Using a 16-channel PiDeltaSigma converter with 4th order delta-sigma modulators and oversampling rate of 6, the simulation results show a 90 dB reduction in unwanted tones caused by 1% gain mismatch