• DocumentCode
    3624430
  • Title

    Electromagnetic Field Measurements In Student Microwave Laboratory

  • Author

    Kresimir Malaric;Sandra Antesevic Maricic

  • Author_Institution
    Faculty of Electrical Engineering and Computing, Unska 3, HR-10000 Zagreb, Croatia. E-mail: kresimir.malaric@fer.hr
  • fYear
    2006
  • Firstpage
    57
  • Lastpage
    60
  • Abstract
    This paper presents the measurements of the electromagnetic fields present in the student microwave laboratory. Due to the high altitude and vulnerability to the ambient electromagnetic fields, it was interesting to see if the level of exposure to microwave frequencies in the laboratory exceeds the international and Croatian standards. The measurements were done in the frequency range from 75 MHz to 3 GHz. The highest fields were from the nearby base station, but still only 0.25 V/m, which is app. 0.5% of the reference level, while the measured radiation from the mobile phone showed peak value of 30 V/m during call, or app. 0.9% of the reference level
  • Keywords
    "Electromagnetic fields","Microwave measurements","Electromagnetic measurements","Laboratories","Magnetic field measurement","Protection","Frequency","Magnetic fields","Electric variables measurement","Guidelines"
  • Publisher
    ieee
  • Conference_Titel
    Software in Telecommunications and Computer Networks, 2006. SoftCOM 2006. International Conference on
  • Print_ISBN
    953-6114-90-9
  • Type

    conf

  • DOI
    10.1109/SOFTCOM.2006.329720
  • Filename